• Getting the failure error "The PATROL installer upgrade process failed while installing due to existing files being used by active processes on the system" while upgrading the patrol agent from 9.6 and 10.7 version (we have both versions) to 11.0 version.

    Getting the failure error "The PATROL installer upgrade process failed while installing due to existing files being used by active processes on the system" while upgrading the patrol agent from 9.6 and 10.7 version (w...
    Mayur Jejurkar
    created by Mayur Jejurkar
  • ADDM discovers running software or installed softwate??

    ADDM discovers running software or installed softwate??
    Farah Naaz
    last modified by Farah Naaz
  • BMC Patrol Agent service is not starting on local computer.

    Hi, I'm unable to restart BMC Patrol Agent service on Local Computer. Error 1067: The process terminated unexpectedly.   Which I have done ? 1: Cross check patrol account & permission. 2: Patrol Agent patch c...
    Manoj Kumar
    last modified by Manoj Kumar
  • bmc-adapter-active-directory-actor

    Hello Friends,   If we wish to have the bmc-adapter-active-directory-actor adapter configured and enabled on a CDP, what all considerations we should keep in mind while designing the workflows?   Any pre-r...
    Shantanu Dubey
    created by Shantanu Dubey
  • Patrol events integration with 3rd party event management tool

    Hello Experts,   We have patrol9.6 has been monitoring 2000+ Unix & AIx machines and the events are reported to the CELLs configured in BEM now.   We have a plan to forward Patrol generated events to H...
    Harikanth Nakireddy
    last modified by Harikanth Nakireddy
  • Remedy Data Archiving

    I need to archive the Remedy 9 data of HPD:Help Desk and all custom forms that I have configured for it for publishing data to other systems. Can someone guide on this. I have identified below forms for archiving i...
    Prinka B
    created by Prinka B
  • C# client for BAO ORCA Web Service

    Hi, Not able to create reference file using WSDL utility provided by Microsoft .NET Throws error related with Security   Any support here please   Regards Rashid
    Rashid Quamar
    created by Rashid Quamar
  • Yellowfin installation 8.9.01

    Hi,   I am facing issue in installing yellowfin 8.9.01. I have gone through all the pre-requisites before installing it and build my lab as it is. However, I am still getting "database validation error" while i...
    Manik Sharma
    last modified by Manik Sharma
  • Can i delete job run folders from target server in transactions folder ?

    PFA screenshot Can i delete job run folders in path /opt/bmc/bladelogic/NSH/Transactions/analysis _archive ?
    saksham gupta
    last modified by saksham gupta
  • Can I delete the stage folder from windows patch repository server as per attached screenshot

    Can I delete the stage folder from windows patch repository server as per attached screenshot ? Will it have any impact ?
    saksham gupta
    created by saksham gupta
  • Reg. prerequisites and Scheduling time

    Hi,   I have a requirement in which I have a Control-M job which needs to be executed either by generation of it's Prerequisites or Scheduling time whichever is earlier. Any idea how to achieve this. Thanks. &...
    gopal biswal
    last modified by gopal biswal
  • A alert has generated

    Attempting to flush cli engine instance for service id com.bladelogic.webservices.rest.RESTAuthenticationException: User 'ID' does not have access to the 'BL' role.   Kindly suggest for Resolution.
    Sanjay paital
    created by Sanjay paital
  • I want to know how to take report for the below

    Can i know how to take the log report(day wise,weekly,monthly) in Control-M z-os ? Can i know how to take the Job run status report in Control-M z-os like (Ended ok,Ended Not-ok,JCL error, etc.... ) status wise ? I ...
  • Unable to get snmp adapter to work on rhel 7

    server already has the 5.16 perl installed with P5NCI module   when i enable the snmpv3 and [snmp adapter] on mcxa.conf file and try to start the adapter , i get below message when i start =====================...
    john pereira
    last modified by john pereira
  • Job dependencies

    Hi, Can you please suggest us how to design the job as per below requirements- •When Job_A and Job_B complete successfully, Job_C starts. When Job_C completes successfully, Job_D starts. This is the happy scen...
    gopal biswal
    created by gopal biswal
  • Powershell version check using Blade logic job

    Hello All,   I am trying to write script to check the powershell version in remote servers with below code. i need the out put of the commands to be stored in one target server. the job is executing without any ...
    Sharat Puranam
    created by Sharat Puranam
  • What is the procedure to add a oracle container DB instance to Truesight Operations management 10.7

    What is the procedure to add a oracle container DB instance to Truesight Operations management 10.7 through CMA policy? I know we need to add C## prefix to monitoring username but we are getting error as following- &...
    Harish Upadhyay
    created by Harish Upadhyay
  • how to retrieve status of executed process using Jobid after sometime?

    I am trying to integrate BMC AO with SOAP UI. When a process is executed, generated job id is only giving the status of process once. I need to check the status of that particular job id after some time also. Kindly a...
    Akansha Sharma
    created by Akansha Sharma
  • SLA commitment of BMC RemedyForce Tool with the users

    can anyone let me know about the SLA commitment of BMC RemedyForce Tool with the users.
    Pankaj Gupta
    created by Pankaj Gupta
  • Truesight versions

    Hi,   Can any one let me know the major difference between BMC truesight Infra management version 10.0.0 and 10.7.0.   Thanks, Rajesh L
    Rajesh Lingaraju
    created by Rajesh Lingaraju