Control-M for z/OS/ Control-D "Adapt new environment"  during EXPRESS UPGRADE fails with $MINDPDF WAS SELECTED BUT NOT FOUND

Version 1
    Share:|

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    Control-M for z/OS


    COMPONENT:

    INCONTROL for z/OS


    APPLIES TO:

    all Incontrol for z/OS products version 9.0.03 or 9.0.04



    PROBLEM:

    During Express Upgrade step "Adapt new environment" 
    job NM1COPYA fails with messages:

    IEB177I $MINDPDF WAS SELECTED BUT NOT FOUND IN ANY INPUT DATA SET
    IEB177I $MREPPDF WAS SELECTED BUT NOT FOUND IN ANY INPUT DATA SET .

    and the EXPRESS UPGRADE fails


    CAUSE:

    express upgrade uses same input as the installion does but versions 9.0.03 and 9.0.04 were created via periodic maintenance only


    SOLUTION:

    Copy members $MINDPDF and $MREPPDF from basepref.GNRL132 library to the IOA olprefa.BANNERS library  manually and then repeat this step.