CONTROL-D - Why are the optional security menus are unavailable in IOAICE environment?

Version 1
    Share:|

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    Control-D


    COMPONENT:

    Control-D


    APPLIES TO:

    All CONTROL product



    QUESTION:

    In the installation CLIST: IOAICE
    In option : Security Customization
    Why the optional security options are missing?
    The same problem occurs with CONTROL-D security, the optional choice are not displayed.


    Exemple:

    The panel displayed is like:


    ------------------------------------------------------ Major Steps Selection -----------------------------------------------------
     COMMAND ===>                                                  SCROLL ===> CSR                                                     
                                                                                                                                       
     Environment: C900      Product: IOA                                                                                               
                                                                                                                                       
     Sel values: S Select step     C Mark step as completed    R Reset status                                                          
                 B Browse Step     X Mark step as excluded     ? Help                                                                  
     PF7/PF8  To scroll through all Steps                                                                                              
     ----------------------------------------------------------------------------------------------------------------------------------
           Sel Step Status      Opt Description                                                                                        
           === ==== ======      === ===========                                                                                        
                                                                                                                                       
            .    1  *               Implement IOA Security                                                                            
     ------------------------------> End of Major Steps <----------------------------       
       


    when the following panel is expected:

     ------------------------------------------------------ Major Steps Selection -----------------------------------------------------
     COMMAND ===>                                                  SCROLL ===> CSR                                                     
                                                                                                                                       
     Environment: C900      Product: IOA                                                                                               
                                                                                                                                       
     Sel values: S Select step     C Mark step as completed    R Reset status                                                          
                 B Browse Step     X Mark step as excluded     ? Help                                                                  
     PF7/PF8  To scroll through all Steps                                                                                              
     ----------------------------------------------------------------------------------------------------------------------------------
           Sel Step Status      Opt Description                                                                                        
           === ==== ======      === ===========                                                                                        
                                                                                                                                       
            .    1  *               Implement IOA Security                                                                             
            .    2              Y   Link IOA Security Modules                                                                          
            .    3              Y   RACF Security Definition Samples                                                                   
            .    4              Y   TopSecret Security Definition Samples                                                              
            .    5              Y   ACF2 Security Definition Samples                                                                   
            .    6              Y   CONTROL-M Application Server - RACF                                                                
            .    7              Y   CONTROL-M Application Server - TopSecret                                                           
            .    8              Y   CONTROL-M Application Server - ACF2      
                                                              

     ------------------------------> End of Major Steps <----------------------------       
                                              


    ANSWER:

    The known reason for such behavior in IOAICE is when the IOAICE being used is running on a non SMP/E Cloned environment.

    1)

    This is one restriction listed in the manual:
    INCONTROL for z/OS Installation Guide: Installing
    Part 4 - Cloning
    Chapter 13 - Cloning an IOA environment
    Limitations
    .../...
    The SECURITY activity is limited to the customization of the SECPARM member.
    .../...


    2)
    To install the security on the cloned environment you have to:

    On the source environment:
    - Install the security on the source environment using the IOAICE, customization, Security Customization
    - Create a deployment package using: IOAICE, Clone, Deploy IOA Environment, Deploy Changes 

    On the target environment:
    - Deploy the package 
    - Define the entities in your security package if this has not been done
    - Activate the security using the $$SECIOA.qname/*, $$SECCTx.qname/*
    - Restart all the monitors

     