CONTROL-D - How to fix the problem linked to message: CTD915E COMPRESSED DATASET ACCESS METHOD SUBSYSTEM name IS NOT ACTIVE

Version 1
    Share:|

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    Control-D


    COMPONENT:

    Control-D


    APPLIES TO:

    All supported CONTROL-D version.



    QUESTION:

    How to fix the problem linked to messages such as:
    CTD915E COMPRESSED DATASET ACCESS METHOD SUBSYSTEM name IS NOT ACTIVE
    or under CONTROL-D/WebAccess interface:
    CTDGBYE CDAM SUBSYSTEM IS NOT ACTIVE. Code error :8

     


    ANSWER:

    CTD915E and CTDGBYE error message means that the CDAM interface has not been initialized.

    This occurs generally after a new installation, installation of a new version or an IPL.

      The Subsystem is dynamically installed by running procedure IOASINIT
    S IOASINIT,OPTIONS=D
         
       
         
      Check list:
    - Is command "S IOASINIT,OPTIONS=D" launched at IPL time?
    - Was IOASINIT started?
    - Did it run successfully? Check sysout!
    - Are the loadlibs mentioned in procedure APF authorized?
         
       
         
      Documentation:
         
      INCONTROL for z/OS Installation Guide
    Chapter 7 Installing CONTROL-D
    Installation steps
    Step 16 - Start CONTROL-D (optional)
    Step 16.2 - Start CDAM and CONTROL-D (optional)
    S IOASINIT,OPTIONS=D
     
      
         
      INCONTROL for z/OS Administrator Guide
    Chapter 4 CONTROL-D and CONTROL-V
    Initialization, Customization, and Administration Features
    Activating the Compressed Dataset Access Method
    S IOASINIT,OPTIONS=D


    See message details:

    CTD915E COMPRESSED DATASET ACCESS METHOD SUBSYSTEM name IS NOT ACTIVE
    Explanation: The Compressed Dataset Access Method (CDAM) subsystem is not active. To initialize the CDAM, see the section on installation of the CDAM in the CONTROL-D chapter of the INCONTROL for z/OS Installation Guide.
    System action: The CDAM data set is not created.
    User response: Do the following:
    1. If necessary, modify SYS1.PARMLIB as specified in the guide so that CONTROL-D is initialized properly after IPL.
    2. Run the IOASINIT started task to initialize CDAM immediately.
    3. Rerun the job.


    CTDGBYE CDAM SUBSYSTEM IS NOT ACTIVE
    Explanation: A CDAM request was not performed because the CDAM subsystem was not active.
    The request is not performed.
    Corrective Action: Run the IOASINIT procedure to start the CDAM subsystem.

     