Image Copy Plus jobs are generating IKJ56247I messages after RSL1707 applied

Version 1
    Share:|

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    IMAGE COPY PLUS


    APPLIES TO:

    Recovery Plus for IMS V5.0.00; Backup and Recovery Solution for IMS V5.0.00



    PROBLEM:

    The IKJ56247I is being issued for ICP and RVP when processing OSAM databases that also have secondary indexes (Full Function and HALDB).  The problem started with maintenance release RSL1707.

    For ICP processing, the message is issued when image copying the target databases.  It is not necessary to image copy the secondary indexes or PSINDEX's for the message to be issued.   

    For RVP, the problem occurs when IDCAMS(*) is NOT used.  It is not necessary to rebuild the indexes and ILDS's for the message to be issued.  

     


    SOLUTION:

    PTF BQQ3033 for FMID ZBRI500 corrects the problem.  BQQ3033 is available from eFix PTF Distribution Services and from BMC Internet Service Retrieval (BMC ISR).   Optionally, the PTF can also be retrieved from the BMC FTP site using the following sample JCL:

    //*
    //* ------------------------------------------------------------------------- *
    //* The following changes must be made to this sample JCL. (Please maintain
    //* the case sensitivity)
    //* 1. TSO EDIT; CAPS OFF
    //* 2. Add a jobcard
    //* 3. Change "HILVLQ" to a valid high-level-qualifier
    //* 4. Change "mine@company.com" to your email address in the FTPGET step.
    //* 5. This is an SMP/E solution.  Use the PTF file to receive and APPLY
    //*    PTF BQQ3033 for FMID ZBRI500 at maintenance level RSL1707.
    //*
    //* ------------------------------------------------------------------------- *
    //DLET00   EXEC PGM=IDCAMS
    //SYSPRINT DD   SYSOUT=*
    //SYSIN    DD   *
      DELETE HILVLQ.KA143171.PTF.TRS PURGE
      DELETE HILVLQ.KA143171.PTF     PURGE
      SET MAXCC = 0
    //*
    //FTPGET   EXEC PGM=FTP
    //SYSPRINT DD   SYSOUT=*
    //OUTPUT   DD   SYSOUT=*
    //* -----------------------------------------------------*
    //*   Case-sensitive!                                    *
    //* -----------------------------------------------------*
    //INPUT    DD *
       ftp.bmc.com
       anonymous
       mine@company.com
       binary
       cd pub/imsbrs
       locsite lr=1024 rec=fb blk=27648 pri=1    sec=1  tr u=sysda
       get KA143171.PTF.TRS +
           'HILVLQ.KA143171.PTF.TRS' (replace
       quit
    /*
    //*
    //UNPACK01 EXEC PGM=AMATERSE,PARM=UNPACK
    //SYSPRINT DD   SYSOUT=*
    //SYSUT1   DD   DISP=SHR,DSN=HILVLQ.KA143171.PTF.TRS
    //SYSUT2   DD   DISP=(,CATLG),UNIT=SYSDA,
    //            SPACE=(TRK,(1,1),RLSE),
    //            DSN=HILVLQ.KA143171.PTF
    //*
    //DLET01   EXEC PGM=IDCAMS
    //SYSPRINT DD   SYSOUT=*
    //SYSIN    DD   *
      DELETE HILVLQ.KA143171.PTF.TRS PURGE
    /*
    //*


    Article Number:

    000143171


    Article Type:

    Solutions to a Product Problem