In Control-M for Advanced File Transfer, the variable set to the detected file name cannot be used in the POSTCMD of the same job

Version 1
    Share:|

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    Control-M for Advanced File Transfer


    COMPONENT:

    Control-M/CM for Advanced File Transfer


    APPLIES TO:

    Control-M for Advanced File Transfer 8.0.00



    PROBLEM:

    A file transfer (AFT) job is defined to set an AutoEdit variable to the detected file name in the "Advanced" section of the job definition.
    That variable is referenced in the Post execution Command of the same job.

    When the post-execution command executes, the filename variable will not have been updated in accordance with the "Advanced" section of the job definition.


    CAUSE:

    CAR00119611 - User can't use AutoEdit containing detected file name in the POSTCMD of the same job Setting of the AFT filename variable does not finish before Post-execution command starts


    SOLUTION:

    Currently the assigned defect is not scheduled to be included in an upcoming fixpack.

    As an interim workaround, define an OS job as a successor to the AFT job and run the post command via the OS job.