Potential IMS Control Region ABEND S0C4 in module DLAXFP2x when running a DELTA IMS RELOAD of a FAST PATH database.

Version 2
    Share This:

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    BMC System Administration for IMS


    APPLIES TO:

    BMC System Administration for IMS



    PROBLEM:

     

    DELTA IMS
    Versions 6.6.01 and later
    October 25th, 2013
    Tracking IDs BPQ9228 , QM001804896, SLN000015175101, KA
    BMC is alerting users to a problem in the following products for the IBM® IMS™
    environment:
    ¦ DELTA IMS
    Issue
    Potential IMS Control Region ABEND S0C4 in module DLAXFP2x when running a RELOAD of a FAST PATH database.

      


    Abend occurs in module DLAXFP2x at offset x'80A'

      

    Example Registers at ABEND time:

      

    DFS629I IMS CTL TCB ABEND - SYS 0C4              
    DFS629I PSW AT ERROR = 077C2000 8004636A          
    DFS629I MODID = DLAXFP24 ZDLA660  EPA = 205A3B08   
    DFS629I R0-3   1E43C000 1E43C000 1E60C000 00003811 
    DFS629I R4-7   208B4FF8 17F84120 17F6C000 0004E644 
    DFS629I R8-11  00069720 00B370D0 1F845F40 00B36078 
    DFS629I R12-15 00045B60 002B0090 8004634C 00000000 

      


    For more information, search the Knowledge Base for a relevant tracking ID. You can
    access the Knowledge Base directly at https://kb.bmc.com/infocenter or from the
    BMC Support Central website (http://www.bmc.com/support).
     

     


    SOLUTION:

     

    Legacy ID:KA404442

      

    The following table provides information about the PTF that resolves this issue:
    Version PTF            Issue                 Defect                PTF Solution                  
    6.6.01    BPQ9228 ISS04198237  QM001805504 SLN000015175101      

      

    You must restart the IMS Control region to make the PTF change effective.

      

    BMC recommends using BMC Internet Service Retrieval (ISR) to obtain PTFs. For
    information about ISR, see your product’s installation guide.

      

    You can also obtain PTFs from eFix PTF Distribution Services (eFix). You can access
    eFix directly at http://efix.bmc.com or from the support site.
    Where to get the latest product information
    To view the latest BMC documents, see the Support Central website at
    http://www.bmc.com/support. Notices such as flashes, technical bulletins, and
    release notes are available on the website. You can subscribe to proactive alerts to
    receive e-mail messages when notices are issued or updated. For more information
    about proactive alerts, see the Support Central website.

      

    NOTE
    If you have questions, contact Customer Support at 1 800 537 1813 (United States or Canada)
    or call your local support center.

      
    Related Products:  
       
    1. DELTA IMS VIRTUAL TERMINAL
    2.  
    3. DELTA IMS for DBCTL
    4.  
    5. DELTA IMS DB/DC

     


    Article Number:

    000085363


    Article Type:

    Solutions to a Product Problem



      Looking for additional information?    Search BMC Support  or  Browse Knowledge Articles