IMS SYS 800-04 abend when executing an ADD DB AUTO=Y (reload sensitive ACBs) or RELOAD DB AUTO=Y (reload sensitive ACBs) when an extremely large PSB is reloaded.

Version 2
    Share This:

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    DELTA IMS DB/DC


    APPLIES TO:

    DELTA IMS DB/DC



    PROBLEM:

     

        
      
      BMC is alerting users to a problem in the following products for the IBM IMS environments:
      
        
      
      -DELTA IMS for DBCTL      
      
      -DELTA IMS DB/DC          
      
      -DELTA IMS VIRTUAL TERMINAL
      
        
      
       
       Issue 
       
          
       
       An IMS SYS 800-04 abend may occur when executing an ADD DB AUTO=Y (reload sensitive ACBs)  
       
       or RELOAD DB AUTO=Y (reload sensitive ACBs) when an extremely large PSB is reloaded. 
       
          
       
       If the PSB size of the PSB being reloaded exceeds the blocksize  
       
       of the ACBLIB dataset, and the LRECL size of the ACBLIB dataset 
       
       is greater than 0 (zero), then an IMS SYS 800-04 abend 
       
       is may occur. 
       
          
       
       This abend problem affects DELTA IMS version 6.6.01. and 6.7.00.  
       
          
       
          
       
       The following items are examples of the IMS SYS 800-04 
       
       abend registers at the time of abend: 
       
          
       
       DFS629I IMS CTL TCB ABEND - SYS 800 
       
       DFS629I PSW AT ERROR = 070C2000 818DD220 
       
       DFS629I MODID = UNKNOWN           EPA = UNKNOWN 
       
       DFS629I R0-3   35000301 8018A000 818DD138 80FE77A2 
       
       DFS629I R4-7   7F73F330 80FE63A8 00FCECD0 007CF8F8 
       
       DFS629I R8-11 028E732C 00000000 00276000 7F73F330 
        DFS629I R12-15 00000000 00272000 80278000 00000004

     


    SOLUTION:

     

    Legacy ID:KA414589

      

     

      
      The following table provides information about the PTF that resolves this issue:

      
      Version 6.6.01 - PTF BPQ9902 - Defect QM001849215 – Solution SLN000015180583 - Knowledge Article KA414589 
    Version 6.7.00 - PTF BPQ9903 - Defect QM001849216 - Solution SLN000015180585  - Knowledge Article KA414589
      
        
      
      You must restart IMS (any type of restart) to make the PTF change effective.

      
        
      
        
      
      Until you apply the correcting PTF, you can avoid the abend by
      
        
      
      1) Execute ADD DB AUTO=N (do not reload sensitive ACBs) or
      
      RELOAD DB AUTO=N (do not reload sensitive ACBs).
      
                         
      
      2) Manually issue a DELTA IMS reload for each ACB
      
      referencing the DB.
      