Log Analyzer for IMS (version 1.4) 0C4 abend or loop (hang) may occur in LUILGFAx when processing Mainview for IMS version 5.1 x�FA� log records.

Version 2
    Share This:

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    BMC Log Analyzer for IMS


    APPLIES TO:

    BMC Log Analyzer for IMS



    PROBLEM:

     

    Log Analyzer for IMS (version 1.4) 0C4 abend  or loop (hang) may occur in LUILGFAx when processing Mainview for IMS version 5.1 x’FA’ log records.

      
      MVIMS 5.1 Log Records changed and increased the size of the FA record by 8 Bytes. When more than one DB is
      
      referenced by the application the DBT List count (MVIMS field) is miscalculated by Log Analyzer.

     


    SOLUTION:

     

    Legacy ID:KA417283

      

    The following table provides information about the PTF that resolves this issue:

      
      Version 1.4.00 - PTF BPQ9794 - Defect QM001828933 – Solution SLN000015179644 - Knowledge Article KA417283  

     


    Article Number:

    000032970


    Article Type:

    Solutions to a Product Problem



      Looking for additional information?    Search BMC Support  or  Browse Knowledge Articles