Dynamic CPU-ID Refresh for DELTA  PLUS, DELTA IMS, and ETA may fail when Mainview for IMS is running and the product authorization module is located in the BMCPSWD DD in the IMS Control Region Start Proc and not in the IMS Steplib.

Version 2
    Share This:

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    BMC System Administration for IMS


    APPLIES TO:

    BMC System Administration for IMS



    PROBLEM:

     

    Dynamic CPU-ID Refresh for DELTA  PLUS, DELTA IMS, and ETA may fail when Mainview for IMS is running and the product authorization module (xxxTBL3y, where xxx = DLP or DLA or ETA and y = T or P)

      

    is located in the BMCPSWD DD in the IMS Control Region Start Proc and not in the IMS Steplib.

      

    Mainview for IMS de-allocates the BMCPSWD DD in the IMS Control Region after IMS initialization. The de-allocated BMCPSWD library prevents dynamic CPU-ID password refresh for:

      

    DELTA PLUS

      

    DELTA IMS

      

    ETA  

      

     

     


    SOLUTION:

     

    Legacy ID:KA417471

      

    The following Mainview for IMS PTF resolves this issue:

      
      Mainview for IMS PTF BPZ0738 – Defect QM001823148 - Solution SLN000015178910 - Knowledge Article KA417471
      
        
      
      Note: Until Mainview for IMS PTF BPZ0738 is applied you may work around this problem by copying the password load module (xxxTBL3y, where xxx = DLP or DLA or ETA and y = T or P)
      
      from the BMCPSWD library to the product loadlib in the IMS Steplib, and then perform dynamic CPU-ID refresh.    
      
    Related Products:  
       
    1. EXTENDED TERMINAL ASSIST PLUS
    2.  
    3. DELTA PLUS VIRTUAL TERMINAL
    4.  
    5. DELTA PLUS for DBCTL
    6.  
    7. DELTA PLUS
    8.  
    9. DELTA IMS VIRTUAL TERMINAL
    10.  
    11. DELTA IMS for DBCTL
    12.  
    13. DELTA IMS DB/DC

     


    Article Number:

    000082681


    Article Type:

    Solutions to a Product Problem



      Looking for additional information?    Search BMC Support  or  Browse Knowledge Articles