An invalid window length error occurs on panel AESIP058 during APPLICATION RESTART CONTROL configuration

Version 2
    Share This:

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    APPLICATION RESTART CONTROL for DB2


    APPLIES TO:

    APPLICATION RESTART CONTROL for DB2



    PROBLEM:

     

    APPLICATION RESTART CONTROL for IMS 3.9.00

    An invalid window length error occurs on panel AESIP058 during APPLICATION RESTART CONTROL configuration

      

    Issue:
    When executing the configuration process for APPLICATION RESTART CONTROL the following window length error occurs on the AES Install System Miscellaneous Data Set Names (AESIP058) panel:

      

    Invalid window depth value (must be numeric, > 0, less than screen depth)
    The problem occurs because the window length in the CLIST is incorrectly specified as follows:

      

    )BODY WINDOW(80,27)

      


    It should be specified as follows:

      


    )BODY WINDOW(80,24)

     


    SOLUTION:

     

    Legacy ID:KA409339

      

    Resolution:
    PTF BPQ9354 resolves this issue. You can obtain PTFs from eFix PTF Distribution Services (eFix). You can access eFix directly at http://apps.bmc.com/support/efix.cgi or from the support site.


    Workaround:
    Until you apply the correcting PTF, you can avoid the problem by editing member AESIP058 in your ARCCUST library to correct the body window length.
    In member AESIP058, change the body window length from (80,27) to (80,24).

      