How do I globally modify the color attributes of Alerts within AutoOPERATOR?

Version 2
    Share This:

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    MainView AutoOPERATOR


    APPLIES TO:

    MainView AutoOPERATOR



    QUESTION:

    How do I globally modify the color attributes of Alerts within AutoOPERATOR?


    ANSWER:

    There is no BBPARM member that allows the user to globally change the color assigned to a priority value for an Alert in AutoOPERATOR. However, an ALRT Rule within AutoOPERATOR can modify an Alert, and color is one of the attributes that can be modified.  This can either be defined at the creation of the Alert, otherwise it is possible to MODIFY the Alert with an ALRT Rule. This is detailed in the steps below (for clarity, it may be necessary to cut and paste the screenshots into Notepad to preserve screen formatting)

    1.  From within AutoOPERATOR, Go into Rules
    2.  Select a Ruleset
    3.  ADD a new Rule
    4.  Make the event type - ALRT
    5.  Use an asterisk for the TEXT of the alert, to say 'all alerts'
    6.  On the SV (Variable Dependency panel), check AMFPRIOR EQ WARNING
    7.  Then on the AA panel you want to say MODIFY and then put the color of your choice in the color field (the example below changes WARNING to use GREEN)

    Using this method, you can make global changes to the Alerts that come to AutoOPERATOR.


    BMC Software  ------------- Selection Criteria - ALRT ------------ AutoOPERATOR
    COMMAND ===>                                                 TGT  --- JO72    
                                                                                  
           Rule-set === AAORULJO             Rule-id  === ALRTRULE                
                                                                                  
    Text Description:                                                             
    Text ID     ===> *                              First Word of Alert           
    Text String (Enter Below):                                                    
                                                                                  
                                                                                  
    Key      ===>                                                                 
    Queue    ===>                                   Alert Queue                   
                                                                                  
    Event    ===>                                   ADD, DELETE, DELETEQ, ANY     
                                                    (default=ADD)                 
                                                                                  
    -------------------------------------------------------------------------------------------------------------

     .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .
    .  BMC Software  ------------ Variable Dependencies - ALRT ---------- AutoOPERATOR .
    .  COMMAND ===>                                                 TGT  --- JO72      .
    .                                                                                  .
    .         Rule-set === AAORULJO             Rule-id  === ALRTRULE                  .
    .                                                                             OR/  .
    .   Variable-name                    Op  Variable-Value                      AND   .
    .                                                                                  .
    .   AMFPRIOR________________________ EQ  WARNING____________________________  ___  .
    .   ________________________________ __  ___________________________________  ___  .
    .   ________________________________ __  ___________________________________  ___  .                                                                              

    ------------------------------------------------------------------------------------------------------------

      .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .
     BMC Software -------------- Alert Action(s) I - ALRT ------------- AutoOPERATOR
     COMMAND ===>                                                 TGT  --- JO72     
            Rule-set === AAORULJO             Rule-id  === ALRTRULE                 
     Function ===> MODIFY                            (ADD, DELETE, DELETEQ, MODIFY) 
     Key      ===>                                                                  
     Text     ===>                                                                  
                                                                                    
                                                                                    
     Queues   ===>                                   Alert Queue Name(s)            
     Priority ===>                                   (CRIT,MAJ,MIN,WARN,INFO,CLEAR) 
     Color    ===> GREEN                             RED,PINK,YEL,DKBL,LTBL,GRE,WHI 
     PCMD     ===>                                                                  
                                                                                    
     System   ===>                                   Return to target after PCMD    
     * EXEC   ===>                                   Follow-up EXEC                 