Abend at Startup of SVOS module in PRPRS004

Version 2
    Share This:

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    MainView SRM Allocation


    COMPONENT:

    MainView SRM Allocation


    APPLIES TO:

    MainView SRM Reporting MainView SRM Enterprise Storage Automation MainView SRM StopX37/II



    QUESTION:

    If a customer receives:

    SVO5052E ERROR ENCOUNTERED IN PRPRS004: SF LOGIC ERROR
    SVO5053I RC=08, RS=052, SUBF=X'00000034,00000001,00000001'
    SVM0090E UNAUTHORIZED ATTEMPT TO USE SVOS 

    Check the libraries in the STEPLIB to ensure that the following load modules reside in at least one of the libraries in the STEPLIB concatenation:

    BBA9BLF0
    BBA9PWRP
    BBA9XBK0
    BLFLO   
    BLFSEC3B
    BLFSEC3S
    SECSEC3B
    SECSEC3S


    If the modules are present in any of the libraries, locate library hlq.PWDLINK, and copy these modules from hlq.PWDLINK to one of the libraries in the STEPLIB or add hlq.PWDLINK to the STEPLIB concatenation . Then try to bring up SVOS again.


    ANSWER:

    Check the libraries in the STEPLIB to ensure that load modules:

    BBA9BLF0
    BBA9PWRP
    BBA9XBK0
    BLFLO   
    BLFSEC3B
    BLFSEC3S
    SECSEC3B
    SECSEC3S


    reside in one of the libraries. If not, locate library hlq.PWDLINK, and copy these modules from hlq.PWDLINK to one of the libraries in the STEPLIB. Then try to bring up SVOS again.

    Also ensure that ptfs BPG7232 and BPG7245 are applied on release 7.8 and BPG7233 and BPG7246 are applied on release 7.7.


    Article Number:

    000118267


    Article Type:

    FAQ/Procedural



      Looking for additional information?    Search BMC Support  or  Browse Knowledge Articles