Control-M for z/OS - What is the reason for getting an S0C3 abend in screen IV on module CTOAPI OFFSET=00002346?

Version 3
    Share This:

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    Control-M for z/OS


    COMPONENT:

    Control-M for z/OS


    APPLIES TO:

    Control-M for z/OS all versions.



    QUESTION:

    What is the reason for getting an S0C3 abend in screen IV on module CTOAPI at OFFSET=00002346?


    SYSTEM COMPLETION CODE=0C3 REASON CODE=00000003
    TIME=09.01.51 SEQ=31483 CPU=0000 ASID=00DB
    PSW AT TIME OF ERROR 078D2000 800FFB4E ILC 4 INTC 03
    ACTIVE LOAD MODULE ADDRESS=000FD808 OFFSET=00002346
    NAME=CTOAPI
    DATA AT PSW 000FFB48 - B04E44F0 B04A980E D12007FE
    GR 0: 00000009 1: 18482CC0
    2: 18482670 3: 1847EF38
    4: 00CDD548 5: 00CD512C
    6: 00C9E000 7: 17A46052
    8: 000FE808 9: 1847EF04
    A: 800EB824 B: 000FFB00
    C: 0004B000 D: 18482690
    E: 800FFB40 F: 00000008
    END OF SYMPTOM DUMP
    Abend 0C3000 hex occurred processing command 'IOATBMN '.


    ANSWER:

     

    Legacy ID:KA388267

      

    This problem occurs because the dataset name(s) defined for DALOAD in the IOADSNL member of IOA PARM is/are not APF authorized.

      

    Please ensure that all dataset names defined as DALOAD in member IOADSNL of the IOA.PARM library is/are APF authorized.

     