CONTROL-M for z/OS - Utility CTMAPI - How to use JOB parameter in an "AJF HOLD" command? It sometimes fails with error message: IOA723I API ENDED UNSUCCESSFULLY REASON  220

Version 2
    Share This:

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    Control-M for z/OS


    COMPONENT:

    Control-M for z/OS


    APPLIES TO:

    All supported CONTROL-M for z/OS version starting from IOA 800.



    QUESTION:

    In the utility CTMAPI, how to use JOB parameter in an "AJF HOLD" command?
    It sometimes fails with error message: IOA723I API ENDED UNSUCCESSFULLY REASON  220


    ANSWER:

    1)
    By default, the parameter JOB is populated when the job has been submitted, else only the MEM name can be used.

    Exemple:
    When a JOB in AJF is in status WAIT_SCH, the following command:
    AJF    HOLD         JOB=jobname    IF STATUS=WAIT_SCH 
    will return message:
    IOA723I API ENDED UNSUCCESSFULLY REASON  220

    2)
    To set the MEM name in the JOB name:
    - set the parameter JNMARORD=Y in section SUBMIT of PARM(CTMPARM)
    - reload the CTMPARM using the modify command: F CONTROLM,NEWPARM

    Sample CTMAPI sysout for SYSIN:

    AJF    HOLD         JOB=jobname    IF STATUS=WAIT_SCH 


    08.01.19 IOA728I ********************************************************************************     
    08.01.19 IOA720I UTILITY CTMUCK    STARTED                                                            
    08.01.19 IOA728I AJF,HOLD,JOB=jobname                                                               
    08.01.19 IOA728I IF,STATUS=WAIT_SCH                                                                   
    08.01.19 IOA72PI ACTION PERFORMED:  HOLD     ON JOB jobname  ORDERID 00001  
    08.01.19 IOA72RI UTILITY CTMUCK    ENDED                                                              
    08.01.19 IOA728I ********************************************************************************    


     