SVO5052E ERROR ENCOUNTERED IN COSSR281: COSSR281 ABEND, but PRECEDED by IBM ICVDSD03 SVOS  CVAF ERROR TYPE 3

Version 1
    Share This:

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    MainView SRM Reporting


    APPLIES TO:

    MainView SRM Reporting release 7.9 and 7.8



    PROBLEM:

    What is causing the CVAF ERROR TYPE 3 dump, followed by error SVO5052E ERROR ENCOUNTERED IN COSSR281: COSSR281 ABEND and SVO3126I ABEND=SB00 in the MainView SRM started task?  
     
                 IEA794I SVC DUMP HAS CAPTURED:  976                                                                              
                 DUMPID=021 REQUESTED BY JOB (SVOS  )                                                                           
                 DUMP TITLE=ICVDSD03 SVOS   CVAF ERROR TYPE 3 TCB= 00AFC2F0 W/A=7F0C9FBC                                      
                                                                                                  
                 SVO5052E ERROR ENCOUNTERED IN COSSR281: COSSR281 ABEND                                                           
                 SVO3125I PSW AT TIME OF ERROR  070C1000 813B49B6 00040013 002FF400  979                                          
                 SVO3126I ABEND=SB00   REAS=0000D3C5  HASN=0075 PASN=0075 SASN=0075                                               
                 SVO3127I PGM=UNKNOWN  LOAD POINT=???????? OFFSET=????????                                                        
                 SVO3128I DATA AT PSW  013B49B0 4010B1F8 000050FE 00009101                                                        
                 SVO3129I AR/GPR CONTENTS:                                        


    SOLUTION:

     

    Please ask the customer if IBM APAR OA57846 matches their symptoms.  (refer to IBM to review entire APAR)

      

    Possible Symptoms:

      

    - ABENDB00 in IECVEXCP or

      

    - ABEND0C4 in IECDSCAN or

      

    -  "ICVDSD03 IEESYSAS CVAF ERROR TYPE 3"

      

    OA57846: ABENDB00 IN IECVEXCP AND ABEND0C4 PIC4 IN IECDSCAN (UA99193) AT IPL TIME OR OTHER INITIATION OF SMF REPO 19/07/22 PTF PECHANGE

      

    Users may also encounter the following message on the console: DUMP TITLE=ICVDSD03 IEESYSAS CVAF ERROR TYPE 3 TCB= nnnnnnnn W/ A= nnnnnnnn
     

      

    ****** Please contact IBM to request the fix for this APAR. ******

      

     

      

    APAR status:

      

    Closed as program error.

      

    Error description:

      

    The initial error will report as an ABENDB00 in IECVEXCP.

      

    Review of dump data will show there is also an ABEND0C4 pic4 in IECDSCAN prior to the ABENDB00.

      

    IECDSCAN is at PTF level UA99193 for Release R2.2.0 of DFSMS.
     

      

    The errors presents to the console as an ABENDB00 in IECVEXCP:

      

    SEARCH ARGUMENT ABSTRACT

      

      PIDS/5752SC1C6 RIDS/NUCLEUS#L RIDS/IECVEXCP AB/S0B00

      

    REGS/C12B8

      

      RIDS/IECVEXFR#R

      

      SYMPTOM             DESCRIPTION

      

      -------             -----------

      

      PIDS/5752SC1C6      PROGRAM ID: 5752SC1C6

      

      RIDS/NUCLEUS#L      LOAD MODULE NAME: NUCLEUS

      

      RIDS/IECVEXCP       CSECT NAME: IECVEXCP

      

      AB/S0B00            SYSTEM ABEND CODE: 0B00

      

      REGS/C12B8          REGISTER/PSW DIFFERENCE FOR R0C:-12B8

      

      RIDS/IECVEXFR#R     RECOVERY ROUTINE CSECT NAME: IECVEXFR

      

    Users may also encounter the following message on the console:

      

    DUMP TITLE=ICVDSD03 IEESYSAS CVAF ERROR TYPE 3 TCB= nnnnnnnn W/

      

    A= nnnnnnnn

      

    Further review of the dump will show an ABEND0C4 in IECDSCAN

      

    (UA99193) in the SYSTRACE output.

      

     

      

    Problem summary

      

    ****************************************************************

      

    * USERS AFFECTED:                                              *

      

    * Users with OA55709 that have enabled SMF                     *

      

    * type 42, subtype 27 (VTOC Audit Log)                         *

      

    * on D/T2017 storage subsystems.                               *

      

    ****************************************************************

      

    * PROBLEM DESCRIPTION:                                         *

      

    * An Abend 0C4 or B00 can occur when                           *

      

    * VTOC Audit Log is being built.                               *

      

    *                                                              *

      

    * Possible Symptoms:                                           *

      

    * - ABENDB00 in IECVEXCP or                                    *

      

    * - ABEND0C4 in IECDSCAN or                                    *

      

    * "ICVDSD03 IEESYSAS CVAF ERROR TYPE 3"                        *

      

    ****************************************************************

      

    * RECOMMENDATION:                                              *

      

    ****************************************************************

      

    KEYWORDS: D/T2107

      

     

      

     

      

     

      

     

      

     

      

     

      

     

      

     

     


    Article Number:

    000184548


    Article Type: