$180APCP apply check failed cc=08

Version 1
    Share This:

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    MAXM Reorg/Online for IMS


    COMPONENT:

    MAXM Reorg/Online for IMS


    APPLIES TO:

    MAXM Reorg/Online for IMS and related IMS Database products.



    QUESTION:

    Customer applies maintenance and the $180APCP job ends with R=0008 because of ++HOLD data  


    ANSWER:

    The Return Code and message is to inform user that they will need to IPL after this maintenance is applied. In order to get passed those messages, they'll need to override the hold as follows:


    BYPASS(HOLDSYS(DOC,ACTION,DB2BIND,DELETE))  to  BYPASS(HOLDSYS(DOC,ACTION,DB2BIND,DELETE,IPL))

    They'll likely encounter this sam condition with other $18nxxxx jobs.


    Article Number:

    000183841