TSSA/BSA: PCI compliance for Solaris 10 failes with error -  "java.lang.unsupportedoperationexception, Error: null"

Version 6
    Share This:

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    BladeLogic Server Automation Suite


    COMPONENT:

    BladeLogic Server Automation


    APPLIES TO:

    BSA 8.9.01



    PROBLEM:

    A Truesight Server Automation (TSSA) PCI compliance job fails with the following error against all Solaris 10 SPARC targets.

    <job run log>

    PCI Data Security Standard - Solaris10 (TARGET) (),Info,"Dec 7, 2018 10:35:39 AM",Compliance execution started for component: PCI Data Security Standard - Solaris10 (TARGET) "compliance PCI XXXXXXX Run at Dec 7, 2018 10:35:27 AM",Error,"Dec 7, 2018 10:35:40 AM","java.lang.UnsupportedOperationException, Error: null" ...
      
    <appserver.log>  
    [07 Dec 2018 10:35:39,837] [WorkItem-Thread-3] [INFO] [BSAUSER:BLAdmins:] [Compliance] __JobRun-170658,5-146532__ Started pid 6828: nsh -c "rm -rf '//TARGET/opt/bmc/bladelogic/NSH/tmp/XXXXX_6eb607ea-16cc-4c20-9eee-af521d0847f7'" [07 Dec 2018 10:35:40,525] [WaitForProcessThread-PID-6828-43082] [INFO] [BSAUSER:BLAdmins:] [Compliance] __JobRun-170658,5-146532__ Process finished: 6828 [07 Dec 2018 10:35:40,540] [WorkItem-Thread-3] [ERROR] [BSAUSER:BLAdmins:] [Compliance] java.lang.UnsupportedOperationException     at java.util.Collections$UnmodifiableCollection.add(Collections.java:1055)     at com.bladelogic.om.infra.ast.visitor.condition.util.AssetUsedInRuleCollectionVisitor.checkAssetPath(AssetUsedInRuleCollectionVisitor.java:288)     at com.bladelogic.om.infra.ast.visitor.condition.util.AssetUsedInRuleCollectionVisitor.visit(AssetUsedInRuleCollectionVisitor.java:87)     at com.bladelogic.om.infra.model.condition.expression.SelectorConditionImpl.accept(SelectorConditionImpl.java:470)     at com.bladelogic.om.infra.ast.visitor.condition.ConditionASTNodeVisitorAdapter.visit(ConditionASTNodeVisitorAdapter.java:142)     at com.bladelogic.om.infra.model.condition.expression.UnaryConditionImpl.accept(UnaryConditionImpl.java:110)     at com.bladelogic.om.infra.ast.visitor.condition.ConditionASTNodeVisitorAdapter.visit(ConditionASTNodeVisitorAdapter.java:94)     at com.bladelogic.om.infra.model.condition.expression.NAryConditionImpl.accept(NAryConditionImpl.java:185)     at com.bladelogic.om.infra.ast.visitor.condition.ConditionASTNodeVisitorAdapter.visit(ConditionASTNodeVisitorAdapter.java:94)     at com.bladelogic.om.infra.model.condition.expression.NAryConditionImpl.accept(NAryConditionImpl.java:185)     at com.bladelogic.om.infra.model.assetselector.AssetSelectorServiceImpl.computeComplianceSelectors(AssetSelectorServiceImpl.java:110)     at com.bladelogic.om.infra.model.assetselector.AssetSelectorServiceImpl.createAssetSelectors(AssetSelectorServiceImpl.java:167)     at com.bladelogic.om.infra.compliance.job.ComplianceJobWorkItemImpl.doWorkItemExecute(ComplianceJobWorkItemImpl.java:518)     at com.bladelogic.om.infra.model.job.workitem.ComponentBasedJobWorkItemImpl.execute(ComponentBasedJobWorkItemImpl.java:122)     at com.bladelogic.om.infra.app.service.workitem.WorkItem.doExecute(WorkItem.java:127)     at com.bladelogic.om.infra.app.service.workitem.thread.WorkItemThread.execute(WorkItemThread.java:176)     at com.bladelogic.om.infra.app.service.workitem.thread.WorkItemThread.execute(WorkItemThread.java:51)     at com.bladelogic.om.infra.app.service.thread.BlBlockingThread.run(BlBlockingThread.java:95) [07 Dec 2018 10:35:40,540] [Job-Execution-4] [ERROR] [BSAUSER:BLAdmins:] [Compliance] __JobRun-170658,5-146532__ java.lang.UnsupportedOperationException, Error: null java.lang.UnsupportedOperationException ...
      
      

     


    CAUSE:

    Cause is known defect (QM002322114), which is fixed in 8.9 SP2


    SOLUTION:

    This is caused by a known issue (QM002322114), which is fixed in BSA 8.9.02.

    Thus the option here would be either to upgrade (BSA & compliance content to the latest) or to open a case to get a workaround (updated template) for 8.9 SP1