    CMFSDV86 IPM SAMPLER SCM TERMINATED, RECORD ERROR X'00000063'
     

    RESPONSE:
     
    Samplers that are actually used by MainView when DC=IPM is configured; IPM, as not writing to SMF or an output file, there is no purpose for having FICONSW (or any of the other samplers not used by MainView) in their IPM configuration.  By using FICONSW with IPM and a ONE minute interval this is exposing a customer to the potential of a time-out.  We have added improved sampler timeout recovery as a RAS item for CMF.   To avoid potential of timeout remove FICONSW from the IPM configuration.  The FICONSW sampler can be used using DC=CPM; CPM configuration writing CMF SMF records.

     