MainView SRM Allocation or StopX37/II 7.9.00 SVOS immediately ends with an SVC DUMP COSSR230 upon startup

Version 1
    Share This:

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    MainView SRM Allocation


    COMPONENT:

    MainView SRM Allocation


    APPLIES TO:

    MainView SRM Allocation 7.9.00 or MainView SRM StopX37/II 7.9.00



    QUESTION:


    Why, after installing or upgrading to 7.9.00 MainView SRM, does the SVOS started task end immediately with an SVC Dump, referencing COSSR230?

     


    ANSWER:

    MainView SRM Allocation or StopX37/II 7.9.00 immediately ends with an SVC DUMP COSSR230 upon startup

    Example messages:
    SVO0703I STARTING SVOS COMMON COMPONENT USING SMMSYS00 RSLxxxx
    ...
    IEA794I SVC DUMP HAS CAPTURED:  196
    DUMPID=003 REQUESTED BY JOB (SVOS    )
    DUMP TITLE=BMC SOFTWARE DIAGNOSTIC DUMP - COSSR230

    The SVOS startup for 7.9.00 fails because the hardware CPU model does not have the z/Architecture facilities needed.  
    The Customer is not able to run or advance to 7.9 of MV/SRM without first upgrading their z/Architecture to ARCH(9) or higher.  
    This requires at least a z196 CPU (2817, introduced in 2010).   Customers who have encountered this have been running z/10 machines with ARCH(8).

    The MVSRM instructions requiring various z/Architecture facilities were inserted into release 7.9 a year after 7.9 was GA.  

    MV/SRM release 7.8 will continue to run on older ARCH(8) systems through 2020, even though IBM will drop support at the end of 2019.

    Reference regarding z/Architecture: https://www.ibm.com/support/knowledgecenter/SSQ2R2_14.0.0/com.ibm.ent.cbl.zos.doc/PGandLR/ui/up0122.html


    Article Number:

    000167114