CONTROL-M JCL Verify - The CTJMON STC fails with SYSTEM COMPLETION CODE=602  REASON CODE=00000000

Version 6
    Share This:

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    Control-M JCL Verify


    COMPONENT:

    Control-M JCL Verify


    APPLIES TO:

    All CONTROL-M JCL Verify



    PROBLEM:

    The CONTROL-M JCL Verify monitor, CTJMON, fails with ABEND S602
    SYSTEM COMPLETION CODE=602  REASON CODE=00000000


    CAUSE:

    This abend is mostly the consequence of a previous failure, for example, Abend S913 when accessing a PROCLIB


    SOLUTION:


    - The abend S602 is mostly the consequence of a previous failure.

    For example: a security issue when opening a library, message:
    CTJ20KE PDS A.PDS.CHECKED.BY.CTJMON                           cannot be accessed due to authorization issue

    This problem will corrupt the memory and the logic and might lead to ABEND S602

    - In the CONTROL-M JCL Verify monitor (CTJMON) search for all the abends and/or messages CTJ20KE
     that occurred before the abend S602.

    - Identify and fix all those problems.

    - Restart the CTJMON once all the problems have been fixed.

     


    Article Number:

    000154484


    Article Type:

    Solutions to a Product Problem



      Looking for additional information?    Search BMC Support  or  Browse Knowledge Articles