What could cause error messages 'BMC278031E UTILITY BUILDER API RC=1,  BMC278038E UUAPI REASON=UTDEF DD POINTS TO A BACK LEVEL OR INCORRECT DATASET'?

Version 2
    Share This:

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    DASD MANAGER PLUS for DB2


    COMPONENT:

    DASD MANAGER PLUS for DB2


    APPLIES TO:

    DASD Manager Plus for DB2



    PROBLEM:

    What could cause error messages 'BMC278031E UTILITY BUILDER API RC=1,  BMC278038E UUAPI REASON=UTDEF DD POINTS TO A BACK LEVEL OR INCORRECT DATASET'?


    SOLUTION:

    This error can occur after an upgrade of DASD Manager if the Trigger JCL was mistakenly not regenerated leaving the UTDEF DD still pointing to the previous release's dataset in error.

    The recommendation is to check the TRIGGER JCL's UTDEF DD and  confirm that it references the new release's XML datasets (hlq.XML) and -if need be- correct.
     

      //*--------------------------------------------------------------------          
    //*        DASD MANAGER WORKLIST EXECUTION                                       
    //*--------------------------------------------------------------------          
    //STEP1 EXEC PGM=AEXEMAIN,                                                       
    //             REGION=0M,                                                        
    //             PARM='ASUDOPD1',MEMLIMIT=NOLIMIT                                  
    //STEPLIB DD  DSN=...                                                            
    -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -   30 Line(s) not Displayed  
    //UTDEF    DD DSN=hlq.UBMCXML,DISP=SHR   <== check to make sure       
    //         DD DSN=hlq.BMCXML,DISP=SHR             <== these datasets are correct 
                                                                                                                          

    The following URL will forward you to the DASD Manager User's Guide:  
          
    The following is stated in the section for "  Setting up a BMCTRIG job
       
      Warning
    To avoid potential job errors, regenerate your BMCTRIG JCL before you run BMCTRIG jobs. Otherwise, you should review DD requirements for potential changes. The UTDEF DD must reference the XML data set by default instead of the CLIST.
     
      
      
      If the cause of this error is not determined, contact BMC Software Customer Support 
      



      

     