PERUSE abend S0C4 when trying to use the live SMF data

Version 1
    Share This:

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    CMF MONITOR



    PROBLEM:

    Using option S to use the current SMF file results in a S0C4 abend.   

    IEA705I ERROR DURING FREEMAIN SYS CODE = 478-08 RDCGXR1 $STD $STD 00
    IEA705I 00F8BE80 0079C338 0079C338 00000300 00000000 00000000
    PS0109E PSCTRL STAE EXIT ENTERED
    PS0902I FORMATTED DUMP TAKEN BY PSCTRL
    IEA995I SYMPTOM DUMP OUTPUT
    SYSTEM COMPLETION CODE=0C4 REASON CODE=00000010
    TIME=13.18.43 SEQ=01669 CPU=0000 ASID=00ED
    PSW AT TIME OF ERROR 478D3000 001CC58A ILC 6 INTC 10
    ACTIVE MODULE ADDRESS=00000000_001CBD00 OFFSET=0000088A
    NAME=PCONTROL
    DATA AT PSW 001CC584 - D2071194 CA18D207 119CE006
    GR 0: 000DE000 1: 001A73D8
    2: 00000000 3: 00000000
    4: 00000000 5: 00000000
    6: 001A73D8 7: 00000000
    8: 00000000 9: 000AB3A8
    A: 00FD9010 B: 00000000
    C: 001CBD00 D: 00066B10
    E: 086BA870 F: 00000000
    END OF SYMPTOM DUMP
    PS0901I BBI/PS STAE EXIT ENTERED FOR
    PS0902I FORMATTED DUMP TAKEN
    PS0911I BBI SOFTWARE RECORD LOGGED TO LOGREC
    PS0109E PSMAIN STAE EXIT ENTERED
    PS0902I FORMATTED DUMP TAKEN
     


    SOLUTION:

    Please download and apply PTF BQM1561.

     FIX DESCRIPTION -                                                   
       CMF 6.2 PERUSE ABENDS WITH AN S478 WHEN USING THE "S" OPTION      
       TO BROWSE THE ACTIVE SMF DATA SET.                                


    Article Number:

    000174401


    Article Type:

    Solutions to a Product Problem



      Looking for additional information?    Search BMC Support  or  Browse Knowledge Articles