How to disable log collection for cyclic job's logs in Control-M Workload Archiving?

Version 1
    Share This:

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    Control-M Workload Archiving


    COMPONENT:

    Control-M Workload Archiving


    APPLIES TO:

    All versions of Control-M Workload Archiving



    QUESTION:

    How to disable log collection for cyclic job's logs in Control-M Workload Archiving?


    ANSWER:

    In order to disable log collection for cyclic job's logs, please update the following system parameter disable.cyclic.log.collection located in {EM_HOME}/archive/config/SystemParameters.xml file to 'always' (instead of never):

    <Parameter>
          <Name>disable.cyclic.log.collection</Name>
          <Value>always</Value>
          <SelectedType>String</SelectedType>
          <Description>enable the option to disable log collection for cyclic jobs (applied to all rules). values are : if_ended_ok, if_ended_notok, always, never </Description>
    </Parameter>

    Recycle the Workload Archiving server from the Control-M Configuration Manager (CCM) and check if the rows in the job_info_working_table table start decreasing after few hours.

    "job_info_working_table " belongs to Control-M Workload Archiving database schema which contains a list of jobs waiting to have log and output collected. You can access the database scheme and use SQL command to query the table through Workload Archiving utility arc_sql which will start an SQL prompt in the Workload Archiving database from Workload Archiving Server.
     