TSSA: 8.9 SP3 Windows patch analysis failed with error - STDERR: Error: 80070057 'class STCore::CInvalidOperationException at Crypto.cpp:532: Invalid data format': parameter name: 'initializeParams'

Version 1
    Share This:

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    BladeLogic Server Automation Suite


    COMPONENT:

    TrueSight Server Automation


    APPLIES TO:

    TSSA 8.9.00 (BSA 8.9 SP3)



    PROBLEM:

    Windows patch analysis failed with the following error:
    - TSSA 8.9 SP3 (BSA 8.9 SP3)
    - RSCD agent version on the target: 8.9.03

    <job run log>
    target,INFO,2018/06/21 9:42:49,"Analyzer execution complete on server: w2k8r2-4 , exitCode: 1"
    target,Error,2018/06/21 9:42:46,STDERR: Error: 80070057 'class STCore::CInvalidOperationException at Crypto.cpp:532: Invalid data format': parameter name: 'initializeParams'
    ...


    <rscd.log>
    06/21/18 09:42:46.202 INFO1    rscd -  xx.xx.xx.xx 5004 TestUser@TARGET->Administrator@TARGET:PrivilegeMapped (BLAdmins:BLAdmin): CM: > Executing command: "C:/Program Files/BMC Software/BladeLogic/RSCD/sbin/BLPatchCheck2.exe" 0 -pc -pt 1 "C:/Program Files/BMC Software/BladeLogic/RSCD/tmp/WindowsCatalog_3962_176_TARGET/WindowsPatchData.zip" "C:/Program Files/BMC Software/BladeLogic/RSCD/tmp/WindowsCatalog_3962_176_TARGET/shavlik_results.xml"
    06/21/18 09:42:47.777 INFO     rscd -  xx.xx.xx.xx 4388 TestUser@TARGET->Administrator@TARGET:PrivilegeMapped (BLAdmins:BLAdmin): mv: mv //TARGET/C/Program Files/BMC Software/BladeLogic/RSCD/tmp/WindowsCatalog_3962_176_TARGET //TARGET/C/Program Files/BMC Software/BladeLogic/RSCD//Transactions/analysis_archive/__JobRun-3962,21-5494__
    06/21/18 09:42:47.793 INFO1    rscd -  xx.xx.xx.xx 4388 TestUser@TARGET->Administrator@TARGET:PrivilegeMapped (BLAdmins:BLAdmin): mv: > 01004 Rename file //TARGET/C/Program Files/BMC Software/BladeLogic/RSCD/tmp/WindowsCatalog_3962_176_TARGET to //TARGET/C/Program Files/BMC Software/BladeLogic/RSCD/Transactions/analysis_archive/__JobRun-3962,21-5494__
    06/21/18 09:42:48.932 INFO1    rscd -  xx.xx.xx.xx 5656 TestUser@TARGET->Administrator@TARGET:PrivilegeMapped (BLAdmins:BLAdmin): CM: > [PatchAnalysis] Deleting //TARGET/C/Program Files/BMC Software/BladeLogic/RSCD//Transactions/analysis_archive/__JobRun-3962,21-5492__
    06/21/18 09:42:52.379 INFO1    rscd -  xx.xx.xx.xx 1232 TestUser@TARGET->Administrator@TARGET:PrivilegeMapped (BLAdmins:BLAdmin): CM: > [PatchAnalysis] Deleting //TARGET/C/BLstorage//patch/analysis/5494/includeExcludeList.obj
    06/21/18 09:42:52.379 INFO1    rscd -  xx.xx.xx.xx 1232 TestUser@TARGET->Administrator@TARGET:PrivilegeMapped (BLAdmins:BLAdmin): CM: > [PatchAnalysis] Deleting //TARGET/C/BLstorage//patch/analysis/5494/.cleanupLock
    ...


    When manually executed the command on the target, it failed with the same error:

    User-added image
     


    CAUSE:

    Agent upgrade issue (not properly updated 'sbin' folder under "[RSCD agent install dir]\RSCD"


    SOLUTION:

    Check the version of 'BLPatchCheck2.exe' with below. This should show as 1.5 with agent 8.9.03 and version 1.6 with 8.9.03 P1

    User-added image

    If it shows as 1.4, it suggests a problem upgrading the agent where this file was not replaced. (perhaps in use or locked at time of upgrade.)

    Uninstall the RSCD agent, clear the existing folder and re-install.


    The second cause:
    New Shavlik content is SHA2-signed, whose signature verification requires certain PKI certificates to be present on the target. These certificates are part of the Microsoft Trusted Root Certificates program and typically require internet access to obtain. If the system being patched does not have internet access or is otherwise prevented from receiving the Root Certificate updates this error can occur. 

    Please refer the below document for Workaround:
    https://docs.bmc.com/docs/tssa89/troubleshooting-patch-management-issues-808908848.html