MainView SRM started task (SVOS) received the following dump: DUMP TITLE=COMPON=VSM-STORAGE,COMPID=SC1CH,ISSUER=IGVRSTOR

Version 2
    Share This:

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    MainView SRM Allocation


    APPLIES TO:

    MainView SRM 7.9 and 7.8 - All products under the MainView SRM umbrella



    QUESTION:

    What caused the MainView SRM started task (SVOS) to receive the following abend:

    04.15.18 STC01234  IEA794I SVC DUMP HAS CAPTURED:  735                        
       735             DUMPID=003 REQUESTED BY JOB (MVSRM   )                     
       735             DUMP TITLE=COMPON=VSM-STORAGE,COMPID=SC1CH,ISSUER=IGVRSTOR 


    ANSWER:

     

    The abend occurred after an F SVOS,SHUTDOWN command was issued to shutdown MainView SRM.

    ***The customer determined that after the SVOS shutdown command was given, the technicians canceled the task because it was not coming down fast enough, which caused the abend.*** 
                                                                          

      

    INFORMATION FOUND IN DUMP:
    IBM purgeQ modules are issuing SVC D (abend) as SVOS has almost completed a planned shutdown.

    IBM rtn died with 47B during SHUTDOWN of SVOS.

    AB/S047B found in dump:                                                                            
       Explanation: An error occurred during PURGEDQ processing. The SDWACRC field of the system diagnostic work area (SDWA) contains a hexadecimal reason code that explains the error.                                                            
     
    Code  Explanation:   

    08                                                                             
        During processing of a PURGEDQ macro for the current primary address space, the system found a preemptable SRB meeting the purge parameters.     The system abended the SRB routine to ensure that all SRB routines 
    affected by PURGEDQ had run to completion.      
                              

    System action: The system abnormally ends the SRB routine.  
     

     


    Article Number:

    000170913


    Article Type:

    FAQ/Procedural



      Looking for additional information?    Search BMC Support  or  Browse Knowledge Articles