NGT terminate utility not working

Version 1
    Share This:

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    Next Generation Technology Load for DB2 for z/OS


    COMPONENT:

    Next Generation Technology Load for DB2 for z/OS


    APPLIES TO:

    Classic DB2 Utilities, SmartSwitch



    PROBLEM:

    Customer running a LoadPlus job with SmartSwitch was unable to terminate the utility in NGT.


    SOLUTION:

    When terminating a SmartSwitch utility, the same classic utility (i.e. LoadPlus) should be submitted with the correct parameter.  You should use either "RESTART" to restart the NGT utility, "TERM" to QUICKEXIT the NGT utiltity, or "FORCEID" to pass that to NGT.  

    The only time you can specify "FORCEID" is if the first time the Classic Utility ran it switched to NGT. 


    Article Number:

    000166299


    Article Type:

    Solutions to a Product Problem