    PROBLEM:

    Active and Past events are not loading after 19.02 upgrade or a fresh install.


    SOLUTION:

    This problem relates to a known defect (DRIIT-35950) and will be addressed in the next cumulative hot-fix. Please use the following workaround until then:

    1) Log into the Mid-Tier as an Administrator and open the "AP:Process Definition" form

    2) Check value of ‘Require Justification on Rejection’ field for all process. 

    ·        Yes
    ·        No
    ·        Clear

    It should be Yes or No and NOT clear.