BMC097805E 001 REPOSITORY CONVERSION TO EXTENDED RBA REQUIRED

Version 1
    Share This:

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    Log Master for DB2



    PROBLEM:

     


    SOLUTION:

    Unless a new Log Master repository is used following migration to IBM DB2 Version 11 New Function Mode, the existing Log Master repository needs to be converted in much the same way as the DB2 catalog for RBA and LRSN values.

    Beginning with Log Master 11.1, the Log Master repository supports extended 10-byte RBA and LRSN values. When running under DB2 11 NFM, the repository must contain only 10-byte RBA and LRSN values. Problems arise if the repository contains both non-extended 6-byte values and 10-byte extended values. This was documented in Log Master for DB2 11.1.00 Technical Bulletin Tracking number QM001863575: Problems might occur when you access an existing Log Master repository after migrating to IBM DB2 Version 11 new-function mode (DB2 11 NFM) dated February 12, 2015

    For more information, see Knowledge Article 000105105 / 
    000315616 on BMC Support Central.