How to resolve BMC24062 and IEC161I 076-002 for Data Collector VSAM datasets?

Version 2
    Share This:

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    MainView for DB2


    APPLIES TO:

    Apptune for DB2, BMC MainVIew for DB2 management, System Performance for DB2, SQL Performance for DB2, BMC Performance for DB2 SQL (all supported versions)



    QUESTION:

    How to resolve BMC24062 and IEC161I 076-002 for Data Collector VSAM datasets?

    //DOMPROF  DD DISP=SHR,DSN=?BMC-HLQ?.PROFILE    ** PROFILE DATASET
    //DOMHELP  DD DISP=SHR,DSN=?BMC-HLQ?.HELP       ** HELP DATASET
    //DOMAUTH  DD DISP=SHR,DSN=?BMC-HLQ?.SECURITY   ** AUTHORITY DATASET
    //DOMBARC  DD DISP=SHR,DSN=?BMC-HLQ?.COPYDIR    ** ARCHIVE DIRECTORY

     


    ANSWER:

    BMC24062 and IEC161I 076-002 messages are issued when the Data collector data sets are not initialized.
    The Data Collector VSAM datasets are meant to reused from release to release. Run install job $310VDOM. This job allocates and initializes new VSAM data sets or migrates the existing data sets for the new release.


     