During the startup for MainView SRM, the started task receives SVO0612W START FOR SVALLOC FAILED ON ETIS

Version 2
    Share This:

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    MainView SRM Allocation


    APPLIES TO:

    MainView SRM Allocation V7.8



    QUESTION:

    During the startup of MainView SRM, the started task (SVOS) receives the following messages:
       SVM4161E PRS30810 UNABLE TO FIND REPLACEMENT CODE                                                               
       SVM4161E IEFAB436 ZAP FAILS, SVALLOC CONTINUES                                                                  
       DIS1509E VERIFICATION OF IDAV557A FAILED IN PRS41509                                                            
       DIS0151S RECEIVED RC 00000016 FROM ZAP GENERATION MODULE 
       SVO0400E PROGRAM ETIDYNAM HAD A RETURN CODE X'010'   
      *SVO0612W START FOR SVALLOC FAILED ON ETIS   


    ANSWER:

    Check the SMMSYSxx member being used by the SVOS started task for parameter FORSYSID.
    If you are using the FORSYSID parameter, make sure the SYSID specified is for the system where the MainView SRM started task (SVOS) is running.
    If you still experience the problem after making this change, please open a case with BMC Customer Support.
     
         FORSYSID= SMMSYSxx global parameter
        The FORSYSID global parameter specifies user-defined system IDs that can be included or excluded in a sysplex environment.
         Syntax:
         FORSYSID=sysid 

      TD 
           The SYSID variable represents a one- to eight-character user-defined system ID.
         Default:
         FORSYSID= sysid


      

       
        

       
        
      
        
      
        

     