Control-M/Server version 9.0.00 is not using the OUTGOING_ADDR parameter found in config.dat to direct communication with Control-M/Agents to a specific interface, preventing communication to some hosts.

Version 1
    Share This:

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    Control-M/Server for UNIX and Microsoft Windows


    COMPONENT:

    Control-M/Server for UNIX and Microsoft Windows


    APPLIES TO:

    Control-M/Server 9.0.00 ; Unix / Linux ; Windows



    PROBLEM:

    After upgrading Control-M/Server from version 7.0.00 or 8.0.00 to version 9.0.00, the OUTGOING_ADDR system parameter copied by the upgrade toolkit is not honored by Control-M/Server.
    This can cause communication problems to some Control-M/Agent hosts.


    CAUSE:

    CAR00136336 - OUTGOING_ADDR parameter is copied to config.dat during migration instead of local_config.dat


    SOLUTION:

    In Control-M/Server 9.0.00 the OUTGOING_ADDR parameter was moved to the local_config.dat file.

    To have the Control-M/Server honor this parameter copy the OUTGOING_ADDR parameter and the value from the [Server Home]/ctm_server/data/config.dat file to the [Server Home]/ctm_server/data/local_config.dat file.
    Then stop and restart the Control-M/Server processes.