In TSCO, what are the user privileges needed to use  Sentry connectors to get metrics from Storage systems?

Version 8
    Share This:

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    TrueSight Capacity Optimization


    COMPONENT:

    Capacity Optimization


    APPLIES TO:

    TrueSight Capacity Optimization 10.X



    DETAILS:

    What are the minimum user privileges needed to be set on the ETL when integratin with following storage technologies?:

      - IBM XiV  
    - HP 3PAR  
    - EMC2 XtremIO  
    - EMC2 VMAX 
      
    What are the privileges/permissions needed for the user accounts used to setup integration with the technologies listed above? 

    These are the basic roles for these storage systems: 

    - IBM XiV: Read-Only 
    - HP 3PAR: Role=Browse  

       
      The rest would be: 
      
        
                                                                                                                                                                                                                                                                                                                                                                                                 
    MANUFACTURERMODELUSER PERMISSIONSWAY CONNECTINGOBSERVATIONS
    HP3PAR DIRECTWBEM based monitoring, the CIM server should be enabled




    HITACHI
    G1000Storage Administrator (View Only) User GroupUsing the Embedded SMI-s 
    HUSVMStorage Administrator (View Only) User GroupUsing the Embedded SMI-s 
    VSP G SERIESStorage Administrator (View Only) User GroupUsing the Embedded SMI-s 
     VSP (otras)
    AMS, HUS, USP
    ViewGroupHitachi Device Manager 
     
     
     
     
    EMC
    SymmetrixMonitorEmbedded SMI-s/Standalone SMIS V8.0.3 (and higher) 
    CelerraMonitorEmbedded SMI-S Provider 
    CLARiiON and VNXMonitorEMC SMI-S Provider v4.6 
    XtremIORole Read-OnlyEMC XtremIO Management Server 
    NETAPPClusterRead-onlyDirectMonitoring Based on the Data ONTAP API
     7-ModeRead-onlyDirectMonitoring Based on the Data ONTAP API
      
     
     
     
    Sentry also recommends the troubleshooting tool which can be found on their website to test the connectors against the storage systems to validate that the user has sufficient privileges depending on the technology, these are jar executables which connect to the systems using the credentials over the metrics intended to query:  
      

    http://www.sentrysoftware.com/support/troubleshooting-tools.asp

     