Receiving the following error in the Control-M/Enterprise Manager GUI when trying to access Repository Folder of a Control-M for Informatica job:  CTM5311 CONTROL-M for Informatica: ETL_INFA0001 = This represents an internal error in the Web Services Hub

Version 10
    Share This:

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    Control-M for Informatica


    COMPONENT:

    Control-M for Informatica


    APPLIES TO:

    Control-M for Informatica 8.0.00



    PROBLEM:

    Receiving the following error when trying to access Repository Folder in the Planning Domain for a Control-M for Informatica job.

    CTM5311 CONTROL-M for Informatica: ETL_INFA0001 = This represents an internal error in the Web Services Hub


    CAUSE:

    CAR00135935: Fail to load repository and workflow during job definition on PowerCenter 10.1.1


    SOLUTION:

    CAR00135935 has been resolved in Control-M 9.0.19 fix pack 1.

    In order to upgrade any previous version of Control-M for Informatica to version 9.0.19 fix pack 1 or higher, deploy Control-M Application Pack on that Control-M/Agent.

    For further details about how to deploy Control-M Application Pack, please check the next link:

    http://documents.bmc.com/supportu/9.0.19/help/Main_help/en-US/index.htm#92957.htm