    PROBLEM:

     

    When verifying the IEHPROGM utility UNCATLG command, the following RACF messages are issued to the console                        if the user has no RACF access to the data set being uncataloged:                                                                     ICH408I USER(xxx) GROUP(yyy) NAME(zzz)                                             dsn CL(DATASET ) VOL(volser)                                                     INSUFFICIENT ACCESS AUTHORITY                                                    FROM dsn (G)                                                               Verification results are correct.     

     


    CAUSE:

    product defect


    SOLUTION:

     

    Apply PTF for BMC APAR BJ10361.

      

    For 8.0:  PTF PF03978. This PTF is part of maintenance 8.0.05.

      

    For 9.0:  PTF PG02418. This PTF is part of maintenance 9.0.03.

      

    CAR00100182 addresses this APAR/CCID.

     