    PRODUCT:

    Control-D


    COMPONENT:

    Control-D


    APPLIES TO:

    version 9.



    PROBLEM:

     

    When multiple missions perform PC file transmissions concurretly then the second transmission fails with USER COMPLETION CODE=4093 REASON CODE=00000090                              in module CEEPIPI  and message: CEE5101C During initialization, the callable service BPX1MSS failed.  The system reason code was 0D070201 . The application will be terminated.                                    The problem occurs only when ISOCKAPI=IBM (the default) is used.        

     


    CAUSE:

    product defect


    SOLUTION:

     

    Apply PTF PG03025 (BMC APAR BD10595).

      

    This PTF is part of maintenance 9.0.18.000.

      

    CAR00143274 addresses this APAR/CCID.

       Bypass
    Specify ISOCKAPI=SAS in member IOAPARM.

     