Control-D monitor fails with abend S0C4.

Version 1
    Share:|

    This document contains official content from the BMC Software Knowledge Base. It is automatically updated when the knowledge article is modified.


    PRODUCT:

    Control-D


    COMPONENT:

    Control-D


    APPLIES TO:

    version 7, 8 and 9



    PROBLEM:

    Control-D monitor fails with ABEND S0C4                             

          SYSTEM COMPLETION CODE=0C4 REASON CODE=00000004                   
          NO ACTIVE MODULE FOUND                                            
          NAME=UNKNOWN                                                      

          STC49855 LSCX041 **** ERROR ****                                  
          AMCLOSE(L$COFIL) ---- 00021A Closing file "DALMES"                
          The problem is caused by unexpected closing DALMES file.          
          The change provides the fix to prevent it.  

    ATTENTION!!!!  This CCID should be apply with CCID=BD10604


    CAUSE:

    product defect


    SOLUTION:

    Apply PTF for BMC APAR BD10605     

    For 7.0:  PTF PD03752
    For 8.0:  PTF PF04350
    For 9.0:  PTF PG03161 . This PTF is part of maintenance 9.0.18.000

    CAR00138848 addresses this APAR/CCID.

     


    Article Number:

    000142476


    Article Type:

    Solutions to a Product Problem



      Looking for additional information?    Search BMC Support  or  Browse Knowledge Articles